Radiative transfer schemes : Différence entre versions

De LMDZPedia
Aller à : navigation, rechercher
Ligne 3 : Ligne 3 :
 
* the "legacy" (oldest) radiative scheme: always available. May be selected using the '''iflag_rrtm=0''' option in physiq.def. Note that this schemes also requires using 2 bands in the SW (Short Wave, i.e. visible wavelengths), i.e. setting '''NSW=2''' in physiq.def
 
* the "legacy" (oldest) radiative scheme: always available. May be selected using the '''iflag_rrtm=0''' option in physiq.def. Note that this schemes also requires using 2 bands in the SW (Short Wave, i.e. visible wavelengths), i.e. setting '''NSW=2''' in physiq.def
 
* RRTM, selected with '''iflag_rrtm=1''' (and requiring that '''NSW=6'''), which is available if the GCM has been compiled with the '''-rad rrtm''' option (see  [[WhatIs: The makelmdz fcm script]]).
 
* RRTM, selected with '''iflag_rrtm=1''' (and requiring that '''NSW=6'''), which is available if the GCM has been compiled with the '''-rad rrtm''' option (see  [[WhatIs: The makelmdz fcm script]]).
* ECRAD (implementation is ongoing at the time of writing this) , selected with '''iflag_rrtm=2''', which is available if the GCM has been compiled with the '''-rad ecrad''' option. Three sub-options:
+
* ECRAD (implementation is ongoing at the time of writing this) , selected with '''iflag_rrtm=2''', which is available if the GCM has been compiled with the '''-rad ecrad''' option.
** McICA : Monte Carlo Independent Column Approximation. Assez rapide, comme si on faisait des sondages, on tire une dizaine de sous-colonnes.
+
 
** triple cloud : trois colonnes par maille : ciel clair, nuageux compact, nuageux intermédiraire. Le plus proche de RRTM.
+
ECRad has three sub-options for the treatment of clouds:
** triple cloud avec Spartacus : effet 3D des nuages, multiplie par 5 le temps d'exécution du rayonnement.
+
* McICA : Monte Carlo Independent Column Approximation. Assez rapide, comme si on faisait des sondages, on tire une dizaine de sous-colonnes.
 +
* triple cloud : trois colonnes par maille : ciel clair, nuageux compact, nuageux intermédiraire. Le plus proche de RRTM.
 +
* triple cloud avec Spartacus : effet 3D des nuages, multiplie par 5 le temps d'exécution du rayonnement.
 +
 
 +
ECRad also has two sub-options for the treatment of the gas phase:
 +
* RRTMG
 +
* ECCKD

Version du 3 avril 2023 à 14:31

There are different radiative schemes that can be used in LMDZ:

  • the "legacy" (oldest) radiative scheme: always available. May be selected using the iflag_rrtm=0 option in physiq.def. Note that this schemes also requires using 2 bands in the SW (Short Wave, i.e. visible wavelengths), i.e. setting NSW=2 in physiq.def
  • RRTM, selected with iflag_rrtm=1 (and requiring that NSW=6), which is available if the GCM has been compiled with the -rad rrtm option (see WhatIs: The makelmdz fcm script).
  • ECRAD (implementation is ongoing at the time of writing this) , selected with iflag_rrtm=2, which is available if the GCM has been compiled with the -rad ecrad option.

ECRad has three sub-options for the treatment of clouds:

  • McICA : Monte Carlo Independent Column Approximation. Assez rapide, comme si on faisait des sondages, on tire une dizaine de sous-colonnes.
  • triple cloud : trois colonnes par maille : ciel clair, nuageux compact, nuageux intermédiraire. Le plus proche de RRTM.
  • triple cloud avec Spartacus : effet 3D des nuages, multiplie par 5 le temps d'exécution du rayonnement.

ECRad also has two sub-options for the treatment of the gas phase:

  • RRTMG
  • ECCKD