HowTo: Run an aquaplanet simulation
The aquaplanet configuration
The aquaplanet configuration is a simpler setup than a usual simulation of the Earth's atmosphere in that idealized initial and boundary conditions are used: no topography and imposed surface temperatures over the whole globe (hence the "aqua"). Apart from this, the full physics package is used, just like in a "regular" LMDZ simulation.
aquaplanet parameters
In practice setting up an aquaplanet simulation is simpler as one may start without initial condition files (start.nc and startfi.nc). This requires setting
read_start=n
in run.def
In addition one must specify a value of iflag_phys between 101 and 114 to trigger the aquaplanet mode, e.g.
iflag_phys=101
This will automatically generate initial conditions and trigger the generation of a limit.nc file adapted to the aquaplanet setup. The values of surface temperature that will be put in the limit.nc file depend on iflag_phys (see routines iniaqua and profil_sst in libf/phylmd/phyaqua_mod.F90).
Good to know
Note that to continue an aquaplanet simulation (i.e. using restart.nc and restartphy.nc files from a previous aquaplanet simulation) one should revert iflag_phys to 1.